Re: People are Case SenSiTiVe
Thank you for your constructive feedback. We will add it to our roadmap Regards,Moshe
View ArticleRe: Production support project
Couple of generic points you can consider. 1)make sure you get the documents related to universe design & reports.2) check what are the activities you have to perform as a report developer. you...
View ArticleRe: Assessment Cycle not allocating cost to receiver cost center as per the...
Hi Can you share your screen shot of your report? Also check your segment once again ..your sender CE group may be missing any CE and therefore value is not considering ... kamal
View Articlewith/without further secondary keys
Dear colleagues, Does anyone know what does this clause do, when creating secondary indexes to internal tables? I don't understand the ABAP Help on this topic. Thanks a lot in advance!, Eloi Rossell
View ArticleRe: is it possible to send more times POD in inbound
Hello Sitoo, Did you ever get a partial process to work as you described above ? I have a similar requirement, and can get a partial to send even ( changed coding on the form routine that was setup...
View Articleresource master in "general tab"
Hi All, I would like to add few extra fileds in resource master in "general tab" Please let me know any bapi or badi ? Because I heard that adding extra fields are not possible. RgdsSurendra
View ArticleRe: Affordable Care Act (ACA)
Hello Gautam/Sita/Mathias/or Anyone, Is the AIR PRD the right location to upload the prod file? Since we are producing those files in SAP so I am wondering why is everyone needing to produce the UUID?...
View ArticleRe: Determining user defined parameters in smartforms at runtime
Classe CL_SSF_FB_SMART_FORM. Use method LOAD, then attribute INTERFACE is an internal table of parameters (standard parameters have STANDARD='X').
View ArticleRe: MaxDB MAXDATAVOLUME - is it possible to decrease this parameter?
Hi Daniel, MaxDataVolumes only shows the number of data volumes you can have without restarting the MaxDB instance. No data volume is added automatically. AFAIK the "Automatic Data Area Adjustment"...
View ArticleRe: R_S4_PRE_TRANSITION_CHECKS logs
Hi Ahmad, Before running the report R_S4_PRE_TRANSITION_CHECKS did you implemented all required notes and completed the manual activities mentioned in the note 2182725? Also, before you run the above...
View ArticleRe: Only the owners should be able to change the BEx Query
Hi Jeet, Could you please elaborate a little more in a simplified language ? I mean what steps you are asking me to follow? Regards,Foram
View ArticleRe: Retrofit: not possible to start (Retrofit Entry Loced by user -...
This is the complete error log. @5B\QInformation@Retrofit entry M000000001/DTA-300/DTEK950217 locked by user BDANDOY@5B\QInformation@Check transport objects for request DTEK950217@5B\QInformation@Start...
View ArticleRe: Define a screen layout FPE1
Hi Amlan Thanks for your reply, but SAP does not provide any standard layout ? RegardsAmit
View ArticleRe: PI 7.4 DUAL STACK TO SAP ARIBA INTEGRATION
Please search on SCN. Asking for such links that can be located by searching are obviously not going to help yourself.. finally check the RDS content on service.sap.com/rds for SAP step by step documents
View ArticleRe: How to define a default value into a list
Hello Padmini, This depends on the structure of the data type. Maybe like this: element MyCode : MyCode = { content = "Hugo" }; HTH, Horst
View ArticleRe: Trava processamento F110 - urgente
Gabriel, obrigada esta parada na SM37, exclui.Executei novamente a F110 e voltou a parar no mesmo ponto, onde verifico a configuração para parar em Background ? no aguardo
View ArticleRe: No change of instance-profile possible
Hello Mathias, if the note 2157878 will not help, you can activate authorization check in ST01 to see, which authoriazion is missing. Regards, Alwina
View ArticleRe: Retrieve data - poll from HCP
Nice. Maybe you can still share your solution please, so that the next reader have an answer?
View ArticleRepeat a Key Figure Value in Report
Hi All, I have the below data in my multiprovider, which is combined from 2 cubes MONTHEMPIDSALESTOTALSALESInforpovider03.201512340000C103.201512450000C103.20151001000C103.2015#050000C2 I have to...
View ArticleRe: Stacked Bar Chart valueAxis
Okay, so this is a valid Javascript date if you use: var timeFrom = new Date(myArray[j].DateFrom) You don't need to call getTime(). You just have to tell your dimension binding that its dataType is...
View Article